Digital Archives Initiative
Memorial University - Electronic Theses and Dissertations 1
menu off  add document to favorites : add page to favorites : reference url back to results : previous : next
 
 Search this object:
  
 0 hit(s) :: previous hit : next hit
  View:    
  previous page : next page
Document Description
TitleAn analysis for digital protection of transformers
AuthorGangopadhyay, Amitabha
DescriptionThesis (M.Eng.) -- Memorial University of Newfoundland, 1985. Engineering and Applied Science
Date1984.
Paginationxxi, 303 leaves : ill.
SubjectElectric power systems--Protection; Protective relays; Electric transformers; Signal processing--Digital techniques;
DegreeM.Eng.
Degree GrantorMemorial University of Newfoundland. Faculty of Engineering and Applied Science
DisciplineEngineering and Applied Science
LanguageEng
NotesBibliography : leaves 300-303.
AbstractThis thesis presents an analysis for digital differential protection of transformers. For digital differential protection of transformers, it is of utmost importance to test the algorithms on simulated data of both fault and magnetizing inrush currents. For this purpose, a detailed analysis of inrush current for both single and three-phased transformers are carried out. Computer software package programs are developed to simulate the inrush and fault currents. Measured waveforms of the inrushes are compared with the simulated waveforms and the harmonic contents of both the measured and simulated waveforms are analysed up to 4 cycles. There exists a reasonably good agreement between simulated and measured waves. -- Three algorithms are analysed for the digital differential protection purpose. Discrete Fourier technique has been used as the reference algorithm. Rectangular transform and Walsh function are analysed in detail for their suitability in microprocessor applications for both 16 and 8 samples/cycle basis. Their performances are compared with Discrete Fourier on 16 samples/cycle basis. Rectangular transform and Walsh function are tested on simulated inrush and fault current data under various switching conditions. It is found that the Rectangular transform converges more rapidly than the other transforms during a fault in the transformer. Finally, on-line implementation of this new digital relay is suggested in near future.
TypeText
Resource TypeElectronic thesis or dissertation
FormatImage/jpeg; Application/pdf
SourcePaper copy kept in the Centre for Newfoundland Studies, Memorial University Libraries
Local Identifier75332294
RightsThe author retains copyright ownership and moral rights in this thesis. Neither the thesis nor substantial extracts from it may be printed or otherwise reproduced without the author's permission.
CollectionElectronic Theses and Dissertations
Scanning StatusCompleted
PDF File(35.80 MB) -- http://collections.mun.ca/PDFs/theses/Ganggopadhyay_Amitabha.pdf
CONTENTdm file name307078.cpd